ALANO Club of Kent County

Grand Rapids, Michigan

hvac-engineering

Story

The existing building is an approximately 10,000 square foot, two-story structure with a lower level partially below grade.  The main and upper levels were remodeled for this project.  The addition is a two-story structure, comprising 5,400 square feet.  Several energy saving measures were incorporated into the remodel as well as the addition, including low-e glass throughout.    All lighting is high efficiency and is controlled with occupant sensors.  Energy recovery ventilators connected to packaged rooftop units pre-condition the outside air to reduce heating and cooling loads.  Classic Engineering provided HVAC design for the design-build contractor on this project. This building achieved LEED Certified status.

Facts

  • Title: Alano club of kent county
  • Location: Grand rapids, michigan
  • Postal code: 49503-1121
  • Phase: Complete
  • Green: Leed certified
  • Delivery method: Design-build


Project Identification Number:

PP-CST-BA50-EB0F-485D-6056-0


Status: Completed


Tags

  • other
  • hvac-engineering
  • sustainable-building